Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
1.
Journal of the Korean Balance Society ; : 15-20, 2006.
Article in Korean | WPRIM | ID: wpr-131282

ABSTRACT

BACKGROUND AND OBJECTIVES: To determine the clinical application of otoacoustic emissions (OAE) in screening of cochlear function, author studied changes of OAE in Meniere's disease patients. MATERIALS AND METHODS: The author has measured several parameters of OAE with 34 meniere's patients and 15 normal persons. Pass rate, response amplitude, reproducibility were recorded at TEOAE. Amplitude of DP-gram were measured at 2 F2 frequencies-1000, 2000 Hz. The input/output functions of DPOAE were recorded at 2 F2 frequencies -1001, 2002 Hz (respectively DP-1000, DP-2000). Input/output function were determined based on 2 parameters- maximal level and Detection threshold of DPOAE. RESULTS: 1) TEOAE: Significant lower rate of positive finding was recorded at involved ears (55.8%, 19/34) than normal ears (100%, 30/30). 2) DP-gram: At frequency was 2000 Hz, amplitude of involved ears (n=28, 6.3+/-.5 dB/SPL) was significant smaller than normal ears (n=30, 6.3+/-.5 dB/SPL). 3) DP-input/output function: At maximum DP level of DP-2000, response of involved ears (n=11, 51.6+/-.9 dB/SPL) was significant larger than normal ears (n=22, 48.5+/-.0 dB/SPL). CONCLUSION: Parameters of OAE, such as pass rate of TEOAE, amplitude of DP-gram at 2000 Hz, and maximum DP level of DP-2000 was considered to good indicators for monitoring cochlear function of Meniere's disease. Furthermore, evaluation by changes in the TEOAE & DPOAE combined parameters, appeared to be very useful for detection of subtle change in cochlear function of Meniere's disease.


Subject(s)
Humans , Ear , Mass Screening , Meniere Disease
2.
Journal of the Korean Balance Society ; : 15-20, 2006.
Article in Korean | WPRIM | ID: wpr-131279

ABSTRACT

BACKGROUND AND OBJECTIVES: To determine the clinical application of otoacoustic emissions (OAE) in screening of cochlear function, author studied changes of OAE in Meniere's disease patients. MATERIALS AND METHODS: The author has measured several parameters of OAE with 34 meniere's patients and 15 normal persons. Pass rate, response amplitude, reproducibility were recorded at TEOAE. Amplitude of DP-gram were measured at 2 F2 frequencies-1000, 2000 Hz. The input/output functions of DPOAE were recorded at 2 F2 frequencies -1001, 2002 Hz (respectively DP-1000, DP-2000). Input/output function were determined based on 2 parameters- maximal level and Detection threshold of DPOAE. RESULTS: 1) TEOAE: Significant lower rate of positive finding was recorded at involved ears (55.8%, 19/34) than normal ears (100%, 30/30). 2) DP-gram: At frequency was 2000 Hz, amplitude of involved ears (n=28, 6.3+/-.5 dB/SPL) was significant smaller than normal ears (n=30, 6.3+/-.5 dB/SPL). 3) DP-input/output function: At maximum DP level of DP-2000, response of involved ears (n=11, 51.6+/-.9 dB/SPL) was significant larger than normal ears (n=22, 48.5+/-.0 dB/SPL). CONCLUSION: Parameters of OAE, such as pass rate of TEOAE, amplitude of DP-gram at 2000 Hz, and maximum DP level of DP-2000 was considered to good indicators for monitoring cochlear function of Meniere's disease. Furthermore, evaluation by changes in the TEOAE & DPOAE combined parameters, appeared to be very useful for detection of subtle change in cochlear function of Meniere's disease.


Subject(s)
Humans , Ear , Mass Screening , Meniere Disease
3.
Korean Journal of Otolaryngology - Head and Neck Surgery ; : 142-145, 2005.
Article in Korean | WPRIM | ID: wpr-657149

ABSTRACT

BACKGROUND AND OBJECTIVES: This study was designed to evaluate relation between frequencies of noise and tinnitus in noise-induced hearing loss and to elucidate mechanism of tinnitus in noise-induced hearing loss. MATERIALS AND METHODS: Four factories were selected, of which noise frequencies were different except one factory. Preliminary screening hearing test with a pure tone audiometer on 1000 and 4000 Hz was done. And if the hearing threshold was over 40 dB, history taking, otological examination, tympanometry, pure tone audiometry on 500, 1000, 2000, 4000, 6000 Hz were done. Noise was measured in 125, 250, 500, 1000, 2000, 4000, 8000 Hz. Tinnitus was measured using 1000, 2000, 4000 Hz pure tone. RESULTS: 1) Hearing loss was most severe in the 4000, 6000 Hz range. 2) In A factory, noise was most intense on 4000 Hz, in B factory on 2000 Hz, and in C and D factory on 1000 Hz. 3) Forty-three workers (42.2%) of total 102 subjects complained tinnitus. And frequency of tinnitus was 4000 Hz in 71 ears (89.9%) among 79 ears with tinnius. CONCLUSION: Regardless of the frequency of noise, most workers complain of 4 kHz tinnitus. And it was in accord with frequency of most severe hearing loss in the noise-induced hearing loss.


Subject(s)
Acoustic Impedance Tests , Audiometry , Ear , Hearing , Hearing Loss , Hearing Loss, Noise-Induced , Hearing Tests , Mass Screening , Noise , Tinnitus
4.
Korean Journal of Otolaryngology - Head and Neck Surgery ; : 1058-1063, 2003.
Article in Korean | WPRIM | ID: wpr-656663

ABSTRACT

BACKGROUND AND OBJECTIVES: Hypopharyngeal cancer is notorious for its poor prognosis and severe surgical morbidity with functional deficits. This study was conducted to compare the efficacy between the neoadjuvant chemotherapy followed by radiotherapy and surgery with postoperative radiotherapy in the treatment of hypophayngeal cancer. MATERIAL AND METHOD: Medical records of 64 patients, treated for hypopharyneal cancer at Pusan National University Hospital from March 1986 through May 2000, were retrospectively reviewed. Thirty-three patients were grouped into the chemotherapy and radiotherapy (CRTx) group, who received neoadjuvant chemotherapy and radiotherapy. Thirty-one patients were grouped into the operation and radiotherapy (ORTx) group, who received laryngectomy with or without reconstruction and postoperative radiotherapy. RESULTS: There was no significant difference of three years survival rate between CRTx group and ORTx group (p>0.05). Laryngeal preservation rate was 45% in CRTx group but 3% in ORTx group (p<0.05). CONCLUSION: Although this had not been a randomized study of chemotherapy followed by radiotherapy versus surgery plus postoperative radiotherapy, the survival rate of CRTx group appears to be as identical as ORTx group and more effective in the preservation of the larynx.


Subject(s)
Humans , Drug Therapy , Hypopharyngeal Neoplasms , Laryngectomy , Larynx , Medical Records , Neoadjuvant Therapy , Organ Preservation , Prognosis , Radiotherapy , Retrospective Studies , Survival Rate
SELECTION OF CITATIONS
SEARCH DETAIL